<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-06 10-37-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 44 dBuV EVROPA 2
Pilot RDS Phase Difference
7.1 kHz 3.3 kHz 8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
12 kHz 43 kHz 18987 0,0158
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,20 dBr 0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"EVROPA 2" 2404 10 (Pop M) 1 0 1 1 10:37, 6.05.2024
RT
"- "
AF EON
92.9, 94.6, 99.3, 99.5, 99.7, 101.5, 105.1, 105.5, 106.7 MHz -
FM Scope Max at: 43 kHz MIN: 12 kHz % above 77 kHz: 0,0158 Acquired: 2024/05/06 10:37:13 Total samples: 18987 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600